How Load Capacitance on a Transmission Line Affects Your Signals
If you ever read about transmission lines and integrated circuit datasheets, there is this seemingly mysterious quantity called load capacitance. This value depends on the geometry of the component lead connected to the transmission line, as well as the substrate material and distance to the reference plane on the integrated circuit die. When working with transmission lines, the load capacitance of a component has some important effects on signal behavior seen at the receiver, and it’s important to understand how you can affect the load capacitance in your PCB.
When you need to analyze signal behavior on a transmission line for a given load component, the load capacitance will affect S-parameters and the transmission line’s transfer function, so it needs to be included in high speed/high frequency signal analysis. In addition, the real input impedance at the load is determined by the load capacitance at sufficiently high frequencies. Here’s how you can better understand your load capacitance and determine how it affects signals in a transmission line on your PCB.
What is Load Capacitance?
The load capacitance on an integrated circuit is a parasitic element between the input lead and the nearest reference plane. In other words, the input pad connected to the component and the transmission line will see a shunt capacitance to the common ground reference (assuming the transmission line and the IC share the same ground plane).
This occurs because the pad connected to the transmission line is brought to some voltage as a signal reaches the receiver, but it is separated from the ground plane by the PCB substrate and the integrated circuit die. Note that the pin-package inductance has been omitted for the moment, which would sit as a series element between the transmission line and the pad. The parasitic capacitance between the pad/ground plane in parallel with the lead/die ground plane gives the total load capacitance. This is shown in the circuit diagram below:
Termination
In the example above, the natural solution to addressing the inherent impedance mismatch is to apply termination. Consider shunt termination at the characteristic impedance (either integrated in the IC or applied with an external resistor). At low frequencies, the load impedance appears to be the terminated impedance. However, at high frequencies, the load impedance appears to be entirely due to the load capacitance. The takeaway here is: you’re only able to impedance match over a limited bandwidth due to the load capacitance.
Source-end Capacitance
One might naturally ask, what about the capacitance on the source side of the transmission line? Indeed, there is some source capacitance that determines the driver’s output impedance due to the presence of a pad. This is normally ignored when modeling because the signal that is sourced from the (driver + transmission line) system is only measured outside the driver. Therefore, we basically don’t worry about how the signal got there, just that we can measure what it is. We only need to worry about the input impedance of the (transmission line + load) system.
Transfer Function with Load Impedance
Whatever signal is launched into the transmission line will be affected by the load capacitance. This is then quantified with a transfer function. Intuitively, if you look at the diagram above, the capacitance acts like a shunt element to ground for high frequency components of the signal. Therefore a transmission line connected to a real IC acts like a low-pass filter, even before the signal reaches the load!
Intuition is nice, but how can we quantify this? Thankfully, you can examine the frequency response of the transmission line with a transfer function. This shows you, either in the Laplace domain or the frequency domain, how load impedance and transmission line’s characteristic impedance affect a signal in the frequency domain. You can then convert back to the time domain with a Fourier transform to compare the initial launch signal and the signal received at the load.
To do this, it’s by far easiest to use ABCD parameters for a transmission line. These are related to the S-parameters (insertion loss and return loss) for a single-ended line. The ABCD matrix for a single-ended line is defined in terms of the line’s characteristic impedance and has a similar meaning as S-parameters:
Now plug these values into the following general formula for the transfer function for a two-port network with defined source and load impedance (note the load impedance is shown above):
If we assume the source is matched to the transmission line, we have the following transfer function for the transmission line. I’ve written this in the Laplace domain for the moment:
Note that a very similar equation is presented in the literature on integrated circuit design for an electrically long line (i.e., longer than the critical length). This equation tells you exactly how the signal is affected by a transmission line’s impedance and the load capacitance. Note that, in general, the quantities in this equation are complex (including the propagation constant) and apply in the case where the line has any level of loss.
For this equation to be used for analysis, you need to include all the possible effects that can create distortion and loss in the system. These include:
- Dispersion and losses in the dielectric
- Copper roughness
- Skin effect losses as they relate to copper roughness
See this article to learn more about these sources of distortion and loss in your transmission lines and how to model them analytically.
Analyzing the Effects of Load Capacitance
Using a transfer function makes it very easy to analyze the effects of load capacitance on the transmission line and any propagating signals. This is best summarized in a graph. The plot below shows the transfer function magnitude and phase for a transmission line on FR4 (10 cm stripline, 0.48 mm plane-to-plane thickness/0.198 mm width, dispersionless, Dk = 4.4, loss tangent = 0.02) with 50 Ohm characteristic impedance with parallel termination. The low-pass behavior up to 1-10 GHz is clearly seen in the top plot.
From this plot we see that, as the load capacitance decreases, the low-pass rolloff does not occur until higher frequencies. We can get a few extra GHz of headroom just by using a component with smaller load capacitance. There is less distortion at midrange frequencies (below the first phase inversion) as the phase curve is flatter up to ~10 GHz. Both plots should illustrate the difficulty in impedance matching up to high frequencies in the signal bandwidth. Here, we haven’t even included copper roughness, fiber weave effects, or the skin effect in these calculations.
When working on high speed/high frequency designs, you can only control the parasitic load capacitance seen on a transmission line from the PCB side. The integrated circuit you choose will have a defined input capacitance that can’t be changed. However, there are 3 levers you can pull to control the total load capacitance seen by a transmission line:
- Surface layer laminate thickness. The PCB’s parasitic contribution to load capacitance is proportional to the layer thickness, so using a thinner laminate for the surface layer with an adjacent ground plane helps push rolloff to slightly higher frequencies.
- Laminate dielectric constant. The PCB’s contribution to total load capacitance is proportional to the laminate’s Dk value, so using a low-Dk laminate for the surface layer provides lower total load capacitance.
- Components. A component with a smaller lead size will tend to have smaller load capacitance. Keep this in mind when selecting components if you need to maintain signal integrity out to very high frequencies (~10’s of GHz).
Short Transmission Lines? Use a Circuit Simulator
When the line is electrically small, we don’t need to take a travelling wave approach and we can just use the circuit theory to describe a transmission line. This effectively forms a mismatched Pi network, which also exhibits low-pass behavior at high frequencies. The difference here is that resonances and transients can occur, just like you would see in a standard RLC circuit. To examine this type of system, you can use the circuit simulation tools in your schematic design software to understand signal behavior and design signal behavior to be critically damped.
Whenever you need to model transmission line behavior in pre-layout or simulate signal behavior post-layout, you can use the complete set of CAD tools in Altium Designer®. The integrated EM field solver in Altium Designer and signal integrity simulator lets you examine how load capacitance of standard logic families affects signal behavior in your PCB. You’ll have a complete set of simulation features for your next board.